sales@motortronics.com transfomersales@phasetronics.com +1 727-573-1819 Mon–Fri 9am–5pm EST

1P1 Series

Precise single phase SCR power control — 10 to 600A, 120–575 Vac, resistive/inductive/lamp loads.

1P1 Series

1P1 Series

Single Phase SCR Power Control

Phasetronics Model 1P1 Series of single-phase SCR Power Controllers feature phase angle control to provide smooth proportional output power from 0–100%. Available in load currents from 10 to 600 amperes at line voltages from 120 through 575 volts AC — ideally suited for all resistive, inductive and lamp type loads.

AC Supply Voltage120 – 575 Vac
Amp Ratings10 to 600A
Control Signal4-20 mA, 0-10 Vdc
Load TypesResistive, inductive and lamp
Soft StartStandard feature
Phase Angle Control

Smooth proportional output from 0–100% with pre-engineered standard options.

Soft Start

Built-in soft start feature assures slow-rising output voltage to eliminate current surges.

Lamp Load Capable

Suitable for resistive, inductive, and lamp-type loads in a single product.

Variety of Options

Standard pre-engineered options make 1P1 ideal for system designers and panel builders.

Technical Specifications

Milliamp Input

4–20 mA, Input Impedance 510 Ω

Manual Control

10 kΩ, 2W potentiometer, linear taper (customer provided)

Output Current Rating

20 to 600 Amps (model dependent)

AC Supply Voltage

120 / 208 / 240 / 380 / 415 / 480 / 575 VAC (+10% / -15%, 50/60 Hz)

Type of Loads

Resistive / Inductive / Lamp

Soft Start — Options B, C, D, E

Set for initial half-second of operation at power on. Field adjustable via potentiometer from 0.25 seconds to 60 seconds. Ramp with DC signal change is factory set for 0.1 seconds (adjustable with capacitor change).

Soft Start — Options KB, KC, KD, KE

Set for initial half-second of operation at power on. Field adjustable via potentiometer from 0.5 seconds to 25 seconds. Ramp with DC signal change is factory set for 0.1 seconds (adjustable with capacitor change).

Soft Start — Options V & T

Set for initial half-second of operation at power on. Field adjustable via potentiometer from 1 second to 50 seconds. Ramp with DC signal change is factory set for 0.1 seconds (adjustable with capacitor change).

Hard Firing Gate Pulse

A combination of high-potential gate pulse and rapid rise time prevents SCR damage due to di/dt stress.

Input Adjustments — Gain

4–20 mA (gain potentiometer) — applies to options B, C, D, E, KB, KC, KD, KE

Input Adjustments — Offset

50% of gain maximum

Regulation — Options B, C, D, E, KB, KC, KD, KE

Load voltage regulation of ±2% over a ±10% line voltage input change.

Regulation — Options V & T

Specific to DC voltage applications — current and/or voltage regulation is 0.75%.

Fusing

Integral I²t fuse protects against short-circuit overloads.

Transient Voltage Suppressor

Integral MOV (Metal Oxide Varistor) protects against high-potential transient voltage.

SCR Peak Inverse Voltage (PIV)

1500V

RC Snubber

RC snubber network prevents false firing due to dv/dt characteristics.

Ambient Temperature

Operating range 0°C to 40°C (32°F to 104°F)

Ready to Get Started?

Contact our team for quotes, technical support, or product information.

Request a Quote Technical Support